30A Discharge 30A Charge 13S Li-ion Battery PCM BMS A01
产品简介
This 30A Discharge 10A Charge 13S Li-ion Battery PCM BMS is used for 13S Li-ion Battery Pack.
产品详细信息
30A Discharge 30A Charge 13S Li-ion Battery PCM BMS
BMS Specifications For 13S Li-ion Battery Packs |
|||
Model: Li13S3010-A01S |
|||
No. |
Test item |
Criterion |
|
1 |
Voltage |
Charging voltage |
DC:58.8V CC/CV |
Balance voltage for single cell |
4.20+0.025V |
||
2 |
Current |
Balance current for single cell |
84+10mA |
Current consumption for single cell |
≤20μA |
||
Maximal continuous Charging current |
30A |
||
Maximal continuous Discharging current |
30A |
||
3 |
Over charge Protection |
Over charge detection voltage |
4.20+0.025V |
Over charge detection delay time |
0.5—2S |
||
Over charge release voltage |
4.10+0.025V |
||
4 |
Over discharge protection |
Over discharge detection voltage |
2.80+0.05V |
Over discharge detection delay time |
10-200mS |
||
Over discharge release voltage |
2.9+0.05V |
||
5 |
Over current protection |
Over current detection current |
70+10A |
Detection delay time |
5ms—20ms |
||
Release condition |
Cut load, Automatic Recovery |
||
6 |
Short protection |
Detection condition |
Exterior short circuit |
Detection delay time |
200-500us |
||
Release condition |
Cut load, Automatic Recovery |
||
7 |
Resistance |
Protection circuitry (MOSFET) |
≤20mΩ |
8 |
Temperature |
Operating Temperature Range |
-40~+85°C |
Storage Temperature Range |
-40~+125°C |
||
9 |
Weight |
|
110g |
10 |
Size |
|
L120*W50*T9mm |